- 1. How did a compass needle link electricity and magnetism?
- 2. What push does a magnetic field give a moving charge?
- 3. Why does a wire carrying current get pushed sideways?
- 4. Why does a charge go round in circles?
- 5. How much field does a tiny piece of wire make?
- 6. The field of a ring of current
- 7. A shortcut for symmetric currents: Ampère's law
- 8. How do you make a uniform magnetic field?
- 9. Why do two parallel currents pull together?
- 10. Why does a coil of current turn in a magnetic field?
- 11. Is a loop of current a tiny magnet?
- 12. How does a meter measure current?
- Review
12 of 12·NCERT §4.10·pp. 129–132·6 min
How does a meter measure current?
The big ideaIn a moving coil galvanometer, the magnetic torque \( NIAB \) on a coil is balanced by a spring's twist \( k\phi \), so the pointer turns through an angle \( \phi \) proportional to the current. Add a small resistance in parallel and it becomes an ammeter; add a large one in series and it becomes a voltmeter.
In simple words
Hang a small coil of wire between the poles of a magnet and hold it with a little spring. Send electricity through the coil and the magnet twists it. The spring twists back. The coil stops where the two twists balance, and a pointer on the coil shows how far it turned. More electricity, more turn. That is how the needle in a meter knows how much electricity is flowing.
How it is built
The moving coil galvanometer (MCG) has:
- a coil of many turns, free to turn about a fixed axis;
- a permanent magnet with curved (concave) pole pieces, and a cylindrical soft iron core inside the coil. The core makes the field radial (pointing along the radius, like the spokes of a wheel) and also makes it stronger;
- a spring that twists back against the coil, with a pointer moving over a scale.
The principle
A current \( I \) through the coil gives it a torque, as for any current loop:
\[ \tau = NIAB \]where \( N \) is the number of turns, \( A \) the area of the coil and \( B \) the field. Because the field is radial, the plane of the coil is always along the field whatever angle it has turned to, so \( \sin\theta = 1 \) at every position. The spring supplies a restoring torque \( k\phi \), where \( \phi \) is the angle of twist and \( k \) is the torsional constant of the spring (restoring torque per unit twist, in N m rad⁻¹). The coil comes to rest where
\[ k\phi = NIAB \quad\Rightarrow\quad \phi = \left(\frac{NAB}{k}\right) I \]The bracket is a constant for a given instrument, so the deflection is proportional to the current and the scale can be marked evenly.
Try it: look inside a pointer galvanometer.
Detector, ammeter, voltmeter
As a detector. With the zero in the middle of the scale, the pointer swings left or right depending on the direction of the current. This is how it is used to find the balance point of a Wheatstone bridge.
Why not use it directly as an ammeter? Two reasons. (i) It is very sensitive: only about a milliampere is enough to send the pointer to the end of the scale. (ii) An ammeter goes in series, and the galvanometer's fairly large resistance would itself change the current it is trying to measure.
Ammeter. Connect a small resistance \( r_s \), the shunt, in parallel with the coil. Most of the current goes through the shunt, and only a small known share through the coil. The combined resistance is
\[ \frac{R_G\,r_s}{R_G + r_s} \simeq r_s \quad \text{if } R_G \gg r_s \]which is small, so the meter hardly disturbs the circuit. If the coil gives full-scale deflection for a current \( I_g \) and the meter must read up to \( I \), the two branches share the same voltage: \( I_g R_G = (I - I_g)\,r_s \), so
\[ r_s = \frac{I_g R_G}{I - I_g} \]Try it: measure a lamp's current three ways.
Voltmeter. A voltmeter goes in parallel with the part of the circuit being measured, so it must draw very little current (usually we want it to disturb things by under one per cent). Connect a large resistance \( R \) in series with the coil. The voltmeter's resistance is then \( R_G + R \simeq R \): large. For full scale at voltage \( V \): \( V = I_g(R_G + R) \), so
\[ R = \frac{V}{I_g} - R_G \]Try it: open a multimeter and turn its range switch.
Sensitivity
The current sensitivity is the deflection per unit current:
\[ \frac{\phi}{I} = \frac{NAB}{k} \]A simple way to raise it is to use more turns \( N \). The voltage sensitivity is the deflection per unit voltage across the galvanometer. With \( V = IR_G \),
\[ \frac{\phi}{V} = \frac{NAB}{k}\,\frac{1}{R_G} \]Now double \( N \). The current sensitivity doubles. But twice the turns needs about twice the length of wire, so \( R_G \) also doubles, and the voltage sensitivity stays the same. So raising current sensitivity does not always raise voltage sensitivity, and turning a galvanometer into a good ammeter needs different changes from turning it into a good voltmeter.
(NCERT writes the coil's resistance in this formula as \( R \); it is the galvanometer's own resistance, not the series resistance of the voltmeter.)
Worked example
A galvanometer has resistance \( R_G = 50\ \Omega \) and gives full-scale deflection at \( I_g = 2 \) mA. Convert it into (a) an ammeter reading up to 2 A, (b) a voltmeter reading up to 10 V.
- (a) \( r_s = \dfrac{I_g R_G}{I - I_g} = \dfrac{0.002 \times 50}{2 - 0.002} = \dfrac{0.1}{1.998} \approx \) 0.05 Ω, in parallel.
- (b) \( R = \dfrac{V}{I_g} - R_G = \dfrac{10}{0.002} - 50 = 5000 - 50 = \) 4950 Ω, in series.
Worked example: why the shunt matters
A 6 V cell (no internal resistance) drives current through a 2 Ω resistor; the true current is 3 A. What would be measured with (a) a bare 40 Ω galvanometer in series, (b) the same galvanometer with a 0.01 Ω shunt?
- (a) Total resistance 42 Ω: \( I = 6/42 \approx \) 0.14 A, nowhere near 3 A. (It would also be far beyond its full-scale range.)
- (b) The shunted meter is about 0.01 Ω, total 2.01 Ω: \( I = 6/2.01 \approx \) 2.99 A, almost exactly the true value.
Try it
A galvanometer has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 50 divisions per volt. What is its resistance?
Answer
Don't mix these up
- Ammeter: small shunt in parallel, low total resistance, placed in series. Voltmeter: large resistance in series, high total resistance, placed in parallel.
- An ideal ammeter has zero resistance; an ideal voltmeter has infinite resistance.
- The radial field is what makes \( \sin\theta = 1 \) at every position, and so makes the scale linear.
- Galvanometer
- A sensitive meter that detects and measures small currents.
- Radial field
- A field pointing along the radius everywhere, like wheel spokes, so the coil's plane is always along it.
- Torsional constant, \( k \)
- The spring's restoring torque per unit angle of twist.
- Shunt
- A small resistance in parallel with the galvanometer that carries most of the current.
- Current sensitivity
- Deflection per unit current, \( NAB/k \).
- Voltage sensitivity
- Deflection per unit voltage, \( NAB/kR_G \).
Words to know
To convert a galvanometer into an ammeter, you connect
- a large resistance in series
- a small resistance in parallel
- a large resistance in parallel
The number of turns of a galvanometer coil is doubled, and its resistance doubles too. The voltage sensitivity
- doubles
- stays the same
- halves
Why is the magnetic field in a moving coil galvanometer made radial?
- So that the torque is \( NIAB \) at every position and the scale is linear
- So that there is no torque when the coil turns
- So that the spring is not needed
Picture and video credits