- 1. Galvanic and electrolytic cells: how a cell makes a voltage
- 2. Measuring electrode potential: the standard hydrogen electrode
- 3. Does concentration change the voltage? The Nernst equation
- 4. From voltage to K and ΔG: what E°cell tells you
- 5. How do solutions carry current? Resistance, conductance and conductivity
- 6. Measuring conductivity: the cell constant and molar conductivity
- 7. Why does molar conductivity rise on dilution? Strong and weak electrolytes
- 8. Kohlrausch's law: adding up the ions
- 9. Electrolysis and Faraday's laws: counting electrons
- 10. What comes out? Products of electrolysis
- 11. Batteries and fuel cells: from a torch cell to your phone
- 12. Why does a bicycle rust? Corrosion as a tiny cell
- Review
6 of 12·NCERT §2.4.1·pp. 43–46·5 min
Measuring conductivity: the cell constant and molar conductivity
The big ideaWe find a solution's conductivity by measuring its resistance in a conductivity cell, using AC and a cell constant found once with standard KCl; dividing by concentration then gives molar conductivity, Λm = κ/c.
In simple words
To test how well a liquid carries a flow, you dip two metal plates in it and measure. But a steady one-way flow slowly changes the liquid, so you use a flow that keeps turning back and forth. You also do not need to measure the plates with a ruler: test them once in a liquid whose answer you already know, and that tells you all you need about the plates.
Two problems, two fixes
A Wheatstone bridge measures an unknown resistance accurately. For a solution, two things get in the way:
- Direct current (DC) changes the solution, because ions react at the electrodes. Fix: use alternating current (AC), which keeps reversing so no net reaction builds up.
- A liquid cannot be clipped to the bridge like a wire. Fix: hold it in a conductivity cell.
The conductivity cell and the cell constant
Inside a conductivity cell are two platinum electrodes, each with a coating of platinum black. Each has area \(A\), and they are a distance \(l\) apart. So the solution between them is a column of length \(l\) and cross-section \(A\), with resistance
\[ R = \rho\,\frac{l}{A} = \frac{l}{\kappa A} \]The ratio \(l/A\) is the cell constant, \(G^*\). It has units of length−1 (cm−1 or m−1). Measuring \(l\) and \(A\) directly is awkward and unreliable, so instead we fill the cell with a KCl solution of known κ, measure R, and use
\[ G^* = \frac{l}{A} = R\,\kappa \]Once \(G^*\) is known, any solution's conductivity follows from its resistance in the same cell:
\[ \kappa = \frac{G^*}{R} \]| KCl / mol L−1 | κ / S cm−1 | κ / S m−1 | Λm / S cm2 mol−1 |
|---|---|---|---|
| 1.000 | 0.1113 | 11.13 | 111.3 |
| 0.100 | 0.0129 | 1.29 | 129.0 |
| 0.010 | 0.00141 | 0.141 | 141.0 |
(KCl at 298.15 K. Notice already: κ falls on dilution but Λm rises. Concept 7 explains why.)
Try it: calibrate a cell in the standard, then use it on an unknown.
The bridge
The cell, with unknown resistance R2, is one arm of a Wheatstone bridge with fixed resistances R3 and R4 and a variable resistance R1. The bridge is fed by an oscillator, an AC source in the audio range, 550 to 5000 cycles per second. A detector, such as a headphone, is silent when the bridge is balanced. Then
\[ R_2 = \frac{R_1 R_4}{R_3} \]Today cheap conductivity meters read the conductance or resistance straight off a screen. Water-testing kits for aquariums and RO purifiers use the same idea, since dissolved salts raise κ.
Balance a bridge yourself, with the numbers of the worked example below.
Molar conductivity
Different electrolytes give ions of different charge and size, in different numbers, so κ alone is not a fair comparison. A more meaningful quantity is the molar conductivity, \(\Lambda_m\) (lambda), the conductivity per unit concentration:
\[ \Lambda_m = \frac{\kappa}{c} \]- SI units: κ in S m−1 and c in mol m−3 give Λm in S m2 mol−1. Since 1 mol L−1 = 1000 mol m−3, \(\Lambda_m = \dfrac{\kappa\ (\text{S m}^{-1})}{1000 \times \text{molarity}}\).
- Common units: κ in S cm−1 and c in mol cm−3 give S cm2 mol−1. With molarity M (mol L−1) and 1 L = 1000 cm3:
The two units are linked by 1 S m2 mol−1 = 104 S cm2 mol−1.
Worked example: from a measured resistance to Λm
A conductivity cell filled with 0.010 M KCl (κ = 0.00141 S cm−1) has a resistance of 500 Ω. The same cell filled with 0.050 M NaCl has 125 Ω. Find κ and Λm of the NaCl solution.
- Cell constant: \(G^* = R\kappa = 500 \times 0.00141 = 0.705\ \text{cm}^{-1}\).
- κ of NaCl: \(\kappa = G^*/R = 0.705/125 = 5.64 \times 10^{-3}\ \text{S cm}^{-1}\).
- \(\Lambda_m = \dfrac{5.64 \times 10^{-3} \times 1000}{0.050} = 112.8\ \text{S cm}^2\,\text{mol}^{-1}\).
- In SI: \(112.8 \times 10^{-4} = 1.128 \times 10^{-2}\ \text{S m}^2\,\text{mol}^{-1}\).
Try it. A 0.050 M solution has κ = 6.10 × 10−3 S cm−1. Find Λm in both units.
Answer
Try it. A cell has G* = 0.88 cm−1. Filled with a solution, it shows 40 Ω. What is κ?
Answer
Don't mix these up
- Cell constant = κ × R, and κ = G*/R. It is a property of the cell, not of the solution.
- The "× 1000" in Λm = 1000κ/M converts litres to cm3; it goes with κ in S cm−1.
- AC, not DC, is used so that the solution does not change while you measure.
- Conductivity cell
- A vessel with two platinised platinum electrodes for holding a solution in a circuit.
- Cell constant, G*
- l/A of a conductivity cell; found as R × κ using standard KCl.
- Oscillator
- A source of alternating current, here at 550 to 5000 Hz.
- Molar conductivity, Λm
- Conductivity divided by molar concentration, κ/c.
Words to know
Why is alternating current used to measure the resistance of a solution?
- AC gives a bigger reading
- DC would electrolyse the solution and change it
- Platinum electrodes cannot carry DC
The conductivity of a 0.025 M solution is 3.9 × 10−3 S cm−1. Its molar conductivity is
- 9.75 × 10−5 S cm2 mol−1
- 156 S cm2 mol−1
- 0.156 S cm2 mol−1
Which equation gives the cell constant?
- G* = κ/R
- G* = Rκ
- G* = A/l
Picture and video credits