- 1. Galvanic and electrolytic cells: how a cell makes a voltage
- 2. Measuring electrode potential: the standard hydrogen electrode
- 3. Does concentration change the voltage? The Nernst equation
- 4. From voltage to K and ΔG: what E°cell tells you
- 5. How do solutions carry current? Resistance, conductance and conductivity
- 6. Measuring conductivity: the cell constant and molar conductivity
- 7. Why does molar conductivity rise on dilution? Strong and weak electrolytes
- 8. Kohlrausch's law: adding up the ions
- 9. Electrolysis and Faraday's laws: counting electrons
- 10. What comes out? Products of electrolysis
- 11. Batteries and fuel cells: from a torch cell to your phone
- 12. Why does a bicycle rust? Corrosion as a tiny cell
- Review
2 of 12·NCERT §2.2.1·6 min
Measuring electrode potential: the standard hydrogen electrode
The big ideaNo one can measure the potential of a single electrode, so we agree to call the standard hydrogen electrode zero and measure every other electrode against it.
In simple words
A voltmeter always needs two ends. It can tell you how much higher one side is than the other, never how high one side is on its own. So people picked one side, made with hydrogen gas, and said "this one counts as zero". Now every other side gets a number by comparing it with that one, the way we measure the height of a hill from the level of the sea.
Why we need a reference
The potential of an individual half-cell cannot be measured. A voltmeter needs two electrodes, so it only ever reads the difference between two half-cell potentials: the emf. If we fix the potential of one electrode by agreement, every other one can be found relative to it.
The standard hydrogen electrode
The chosen reference is the standard hydrogen electrode (SHE), written Pt(s) | H2(g) | H+(aq). It is given a potential of zero at all temperatures, for the reaction
\[ \ce{H+(aq) + e- -> 1/2 H2(g)} \]- Its electrode is platinum with a coating of platinum black (finely divided platinum, which gives a large surface).
- It sits in an acid solution while a stream of pure hydrogen gas bubbles past it.
- Both forms of hydrogen are kept at unit concentration: H2 at 1 bar and H+ at 1 M.
Measuring E° of another half-cell
Build a cell with the SHE on the left (as anode) and the half-cell you want on the right (as cathode), at 298 K and unit concentrations. Then
\[ E^\ominus_\text{cell} = E^\ominus_\text{R} - E^\ominus_\text{L} = E^\ominus_\text{R} - 0 = E^\ominus_\text{R} \]so the measured emf is the standard electrode potential of the right-hand half-cell.
Try it: keep the hydrogen electrode on the left and change the half-cell on the right.
- Pt | H2(g, 1 bar) | H+(aq, 1 M) || Cu2+(aq, 1 M) | Cu reads +0.34 V. So E⊖(Cu2+/Cu) = +0.34 V. The plus sign means Cu2+ is reduced more easily than H+. So H+ cannot oxidise copper, and copper does not dissolve in HCl. (In nitric acid copper does dissolve, but it is the nitrate ion that oxidises it, not H+.)
- Pt | H2(g, 1 bar) | H+(aq, 1 M) || Zn2+(aq, 1 M) | Zn reads −0.76 V. So E⊖(Zn2+/Zn) = −0.76 V. The minus sign means H+ can oxidise zinc: zinc gives hydrogen with dilute acid.
Now the Daniell cell, Zn | Zn2+ || Cu2+ | Cu, follows at once:
\[ E^\ominus_\text{cell} = E^\ominus_\text{R} - E^\ominus_\text{L} = 0.34 - (-0.76) = 1.10\ \text{V} \]Inert electrodes
Some half-cells have no metal of their own to use as an electrode. Then an inert electrode, such as platinum or gold, is used. It takes no part in the reaction; it only gives a surface for the reaction and carries electrons. Examples: the hydrogen electrode, Pt | H2(g) | H+(aq), and the bromine electrode, Pt | Br2(aq) | Br−(aq), with \(\ce{1/2 Br2(aq) + e- -> Br-(aq)}\).
The table of standard electrode potentials
Every value is for a reduction: oxidised form + ne− → reduced form, at 298 K. A selection:
| Half reaction | E⊖ / V |
|---|---|
| \(\ce{F2(g) + 2e- -> 2F-}\) | +2.87 |
| \(\ce{MnO4- + 8H+ + 5e- -> Mn^2+ + 4H2O}\) | +1.51 |
| \(\ce{Cl2(g) + 2e- -> 2Cl-}\) | +1.36 |
| \(\ce{Cr2O7^2- + 14H+ + 6e- -> 2Cr^3+ + 7H2O}\) | +1.33 |
| \(\ce{O2(g) + 4H+ + 4e- -> 2H2O}\) | +1.23 |
| \(\ce{Br2 + 2e- -> 2Br-}\) | +1.09 |
| \(\ce{Ag+ + e- -> Ag(s)}\) | +0.80 |
| \(\ce{Fe^3+ + e- -> Fe^2+}\) | +0.77 |
| \(\ce{I2 + 2e- -> 2I-}\) | +0.54 |
| \(\ce{Cu^2+ + 2e- -> Cu(s)}\) | +0.34 |
| \(\ce{AgCl(s) + e- -> Ag(s) + Cl-}\) | +0.22 |
| \(\ce{2H+ + 2e- -> H2(g)}\) | 0.00 |
| \(\ce{Pb^2+ + 2e- -> Pb(s)}\) | −0.13 |
| \(\ce{Ni^2+ + 2e- -> Ni(s)}\) | −0.25 |
| \(\ce{Fe^2+ + 2e- -> Fe(s)}\) | −0.44 |
| \(\ce{Zn^2+ + 2e- -> Zn(s)}\) | −0.76 |
| \(\ce{2H2O + 2e- -> H2(g) + 2OH-}\) | −0.83 |
| \(\ce{Al^3+ + 3e- -> Al(s)}\) | −1.66 |
| \(\ce{Mg^2+ + 2e- -> Mg(s)}\) | −2.36 |
| \(\ce{Na+ + e- -> Na(s)}\) | −2.71 |
| \(\ce{K+ + e- -> K(s)}\) | −2.93 |
| \(\ce{Li+ + e- -> Li(s)}\) | −3.05 |
Reading the table
- Top: F2 has the highest E⊖, so it is most eager to be reduced. F2 is the strongest oxidising agent, and F− the weakest reducing agent.
- Bottom: Li+/Li has the lowest E⊖. Li+ is the weakest oxidising agent, and Li metal the strongest reducing agent in water.
- Going down, oxidising power of the left-hand species falls and reducing power of the right-hand species rises.
- Negative E⊖: the couple is a stronger reducing agent than H+/H2. Positive E⊖: a weaker one. Put another way, positive E⊖ means the reduced form is more stable than hydrogen gas.
Worked example: will it go?
Can chlorine gas oxidise iodide ions to iodine?
- Write it as a cell: I− is oxidised (anode), Cl2 reduced (cathode).
- \(E^\ominus_\text{cell} = E^\ominus_{\ce{Cl2/Cl-}} - E^\ominus_{\ce{I2/I-}} = 1.36 - 0.54 = +0.82\) V.
- Positive, so yes: \(\ce{Cl2 + 2I- -> 2Cl- + I2}\) goes by itself.
Rule: take the cathode minus the anode for the reaction as written. A positive E⊖cell means the reaction is spontaneous.
The table works like a ladder: a couple higher up pulls electrons off any couple below it. Try a few pairs.
Try it. Can you store copper sulphate solution in an iron bucket?
Answer
Cells like these are used to find the pH of solutions, solubility products, equilibrium constants and other thermodynamic quantities, and in potentiometric titrations (titrations followed by watching a cell's voltage).
Don't mix these up
- The SHE is zero by agreement, not because it has no potential.
- Do not multiply E⊖ by the coefficients when you double a half reaction. Potentials are not amounts (concept 4 explains why).
- Copper does not dissolve in HCl, but it does in HNO3, because nitrate, not H+, is the oxidiser.
- Standard hydrogen electrode (SHE)
- Platinum in 1 M H+ with H2 at 1 bar; given 0 V.
- Platinum black
- A coating of very fine platinum that gives a big surface.
- Standard electrode potential, E⊖
- The reduction potential of a half-cell at unit concentrations against the SHE.
- Inert electrode
- An electrode (Pt, Au) that only carries electrons and takes no part in the reaction.
- Potentiometric titration
- A titration whose end point is found from a cell's voltage.
Words to know
E⊖(Mg2+/Mg) = −2.36 V. What does the minus sign tell you?
- Mg2+ is a strong oxidising agent
- Magnesium is a stronger reducing agent than hydrogen
- The value was measured wrongly
Which metal will not give hydrogen gas with dilute HCl?
- Zinc
- Iron
- Silver
E°cell for \(\ce{Ni + Pb^2+ -> Ni^2+ + Pb}\) is
- +0.12 V
- −0.12 V
- −0.38 V
Picture and video credits